TEST AND COMMISSIONING SERVICES

High Voltage Test and Commissioning Services

As Kontrolmatik all test and commissioning work in our projects, from factory acceptance phase to test and commissioning phase, is done by our experienced engineer staff with test devices which are appropriate to international standards.

Kontrolmatik Test and Comm. Brochure

AIS Switchyard Tests

HV switchyard test, maintenance and repair;

  • Transformer all tests, maintenance and repair
  • Surge arrester all tests, maintenance and repair
  • Neutral resistor all tests, maintenance and repair
  • Voltage transformer all tests, maintenance and repair
  • Current transformer all tests, maintenance and repair
  • Circuit breaker all tests, maintenance and repair
  • Isolator all tests, maintenance and repair
  • DC voltage control
  • Protection relay set and tests
  • Measuring device’s tests
  • Control, lubrication and cleaning of mechanical parts
  • Control of primary and secondary cabling
  • SF6 gas/ vacuum addition and control
  • Busbar junction point control and torching
  • Circuit breaker repair and change
  • Separator repair and change
  • Current transformer change
  • Voltage transformer change
  • Current transformer electrical tests
  • Power (% PF, tand, capacity) tests
  • Insulation resistance tests
  • Saturation tests
  • Current ratio tests
  • Polarity tests
  • Winding resistance tests
  • Load tests

Current Transformer maintenance and control;

  • SIMS and ECS environmental control system and mechanic equipment
  • Current transformer terminal cabling control
  • Oil-immersed current transformers’ oil level control
  • Primary binding control and cleaning work Isolator maintenance and control;
  • Contact transition resistance tests
  • Insulation resistance tests

Isolator maintenance and control;

  • Contact maintenance
  • Mechanism lubrication and cleaning
  • Bushing control and cleaning
  • Mechanism set
  • Control panel cabling and hardware control
  • Record of motor current values after maintenance
  • Busbar junction point cleaning and lubrication.
  • Isolator drive motor control

Isolator maintenance;

  • Repair and change
  • Mechanic installations maintenance and change
  • Bearing, gland and ring change
  • Control panel hardware repair and change
  • Isolator drive motor renewal

GIS Switchyard Tests

Circuit breaker electrical tests;

  • Power factor (% PF, tand, capacity) tests
  • Insulation resistance tests
  • Open / Close duration tests
  • Contact transition resistance tests Circuit breaker maintenance and control;
  • Circuit breaker open and close bobbin change
  • Circuit breaker set motor control
  • Circuit breaker spring mechanism control
  • Circuit breaker cabling control
  • Circuit breaker contact maintenance
  • Mechanism lubrication and cleaning.
  • Circuit breaker SF6 gas vacuum level control and addition
  • SF6/ Vacuum tubes renewal
  • SF6 Gas addition, defueling and vacuuming

Voltage transformer electrical tests;

  • Power factor (% PF, tand, capacity) tests
  • Excitation current tests
  • Insulation resistance tests
  • Voltage converter ratio tests
  • Winding resistance tests

Voltage transformer maintenance and controls;

  • Voltage transformer terminal cabling control
  • Primary junction control and cleaning

Protection & IED Tests Protection and control relay systems;

  • Distance protection relay tests
  • Over current and earth relay tests
  • Directional over current and directional earth relay tests
  • Low and high voltage relay tests
  • Low and high frequency relay tests
  • Differential relay tests
  • Busbar protection relay tests
  • Measuring devices and power analyzer tests
  • Unbalanced load relay
  • Metering tests
  • Synchronization check relay tests
  • Substations relay coordination and short circuit calculations
  • Transformer simulation tests
  • Circuit breaker secondary signal tests

Protection and control relays set and tests;

  • Protection and control relays set and tests
  • Transducer tests
  • Metering devices tests

Power Plant Tests

Rotating machines test and maintenance;

  • Type u p (% PF, tand, capacity) tests
  • Insulation resistance tests
  • DC high voltage tolerance tests
  • AC high voltage tolerance tests

Generators / Motors

  • Winding resistance tests
  • Rotor windings impedance tests
  • Pole voltage tests
  • Winding discharge tests

Scada & Communication Tests

SCADA automation;

  • Protection systems’ SCADA adaptation
  • SCADA projects
  • Load rejection automation
  • Integration of electric infrastructure and automation systems
  • Monitoring and reporting

Communication

  • Planning and design of communication projects
  • Identify of communication problems and solution of problems
  • Installation
  • Maintenance and service
  • Development of systems
  • All the processes of communication projects are carried out as turnkey
  • Communication systems project design
  • Panel production and factory assent test
  • Field applications and installation
  • Field testing and commissioning

KONTROLMATIK

We help increase the performance and productivity of power plants, we provide facilities for monitoring and security of switchyards and help delivery of electricity with the lowest possible losses. We achieve these by means of automation systems and electrical infrastructures we design and implement specifically to meet the requirements of our customers operating in the energy sector.

OTHER SERVICES

ICS CYBERSECURITY

**ICS Cybersecurity** Expanding connectivity linking IT and OT with digital and cyber-physical systems means that there is no longer a singular perimeter. Kontrolmatik provides companies layered

Read More

AUTOMATION

Automation and control systems enable efficient and safe operation of industries,process and power plants by minimizing the risks. Monitoring and reporting ensure the opportunity to access all cont

Read More

PROTECTION and CONTROL

**Protection applications in transmission lines** PROTECTION ON ENERGY TRANSMISSION AND DISTRIBUTION LINES To assure reliability of the system, it is important to detect faults at any point on the

Read More
© 2020 - All rights reserved